Unbuild It | Episode 157: Three Guys on Four Highly Technical Building Puzzles
Here is a brief lowdown on each question:
- building on expansive soils requires an engineered foundation and there are several building systems available to manage expansive soil;
- attic radiant barriers make the most sense in Climate Zones 1 - 3;
- follow the priority of the 4 control layers (water 1st, airtightness 2nd, drying potential 3rd, thermal last) and go with placing the WRB where you can get it the most continuous in the least complicated & expensive way;
- avoid configuring a diaper wall assembly (moisture-sensitive wall layer with very low vapor permeability layers on BOTH sides of this layer) whenever you can BUT the more the weather-protected said wall (so it "sees" very little moisture) and make it airtight, the less pressure there is on the vapor permeability of each layer in your assembly.
PETE'S RESOURCES:
- Post-tension slab for expansive soils: https://www.post-tensioning.org/education/tptapplications/slab-on-ground.aspx
- "Evolution of Foundation Design for Expansive Soils" https://ascelibrary.org/doi/pdf/10.1061/40960%28282%29/294?download=true
- ORNL "Thermal Performance Evaluation of Attic Radiant Barrier Systems" https://www.ornl.gov/publication/thermal-performance-evaluation-attic-radiant-barrier-systems-using-large-scale-climate
- Building America Solution Center - Attic Radiant Barriers: https://basc.pnnl.gov/resource-guides/attic-radiant-barriers
- EPA "Moisture Control Guidance for Building, Construction, and Maintenance" https://www.epa.gov/sites/default/files/2014-08/documents/moisture-control.pdf
- GBA "Vapor Profiles Help Predict Whether a Wall Can Dry" https://www.greenbuildingadvisor.com/article/vapor-profiles-help-predict-whether-a-wall-can-dry
Episodes
Unbuild It | Episode 167: Tricky but Cool Assemblies: Vented Over-Roofs & Double-Stud Walls
Episode 167
In this episode of the UnBuild It Podcast, the guys dive into roof ventilation strategies for standing seam metal roofs, including vent spacing, underlayments, and night sky radiation. They also debate double-stud wall assemblies versus ZIP-R sheathing and exterior mineral wool insulation, exploring the pros, cons, costs, and practical challenges of each approach.
Unbuild It | Episode 165: Confusing the cost and value of building science-based, better-performing homes
Episode 165
Steve and Jake emphasize the value of building science in delivering affordable high-performance homes, regardless of client budgets. Additional resources provided by Pete for further reading.
Unbuild It | Episode 164: Thermal Control Layers Explained
Episode 164
In the final episode of the Back to Basics series, Steve, Jake, and Pete break down the thermal control layer, from insulation and R-values to thermal bridging and continuity. Learn why effective thermal performance depends on all four building control layers—water, air, vapor, and thermal—working together.
Unbuild It | Episode 162: Back to Basics: Air Control Layers Explained
Episode 162
The boys break down key building science principles for creating effective control layers, with a special focus on airtightness. From maintaining continuity and simplifying installation to blower door testing and understanding what drives air leaks, this episode offers practical guidance for building tighter, better-performing homes.
Share on facebook
Tweet
Email
Share on Linkedin